ROZWIĄZANIE DOPŁYWU DO STUDNI Z UWZGLĘDNIENIEM POWIERZCHNI SWOBODNEGO WYPŁYWU I PIĘTRZENIA WODY PRZEZ RURĘ NADFILTROWĄ

Authors

  • S. Żak

Keywords:

studnia, powierzchnia swobodnego wypływu, przepływ ustalony, metoda różnic skończonych.

Abstract

A SOLUTION FOR WATER INFLOW TO A WELL IN CONDITIONS OF SEEPAGE SURFACE AND LIFTING WATER WITH A WELL-CASING PIPEThe article presents a solution for steady-state water in flow to an incomplete well located in a homogeneous and orthotropic unconfined water table aquifer. The calculations take account of the surface of seepage in the well and a possibility of lifting water with a well-casing pipe. The aquifer has a horizontal bottom and can be recharged with in filtration waters. The solution was produced in the form of a programme written in Excel spreadsheet with a use of the finite difference method. It is based on Laplace groundwater flow equation in the logarithmic-cylindrical coordinate system. The program enables the calculation of water in flow to a well, the height of seepage face, the size of the depression cone, and it generates graphs of water table position as a function of distance from the well. The preliminary tests demonstrate the consistence of the results obtained by means of the discussed programme with results described in literature. The programme is available free of charge from the website www.ig.pwr.wroc.pl/zaklady/ZGiWM at studnia_zw_swob.xls.